Rapid Determination of alpha(s) 1-Casein and kappa-Casein in Milk Based on Fourier Transform Infrared Spectroscopy

Xiao Shi-jie,Wang Qiao-hua,Fan Yi-kai,Liu Rui,Ruan Jian,Wen Wan,Li Ji-qi,Shao Huai-feng,Liu Wei-hua,Zhang Shu-jun
DOI: https://doi.org/10.3964/j.issn.1000-0593(2021)12-3688-07
2021-01-01
Spectroscopy and spectral analysis
Abstract:In order to find a rapid detection method for the content of two main allergens (alpha(s) 1 and kappa-casein) in milk, 211 Chinese Holstein milk samples from four provinces of Henan, Hubei, Ningxia and Inner Mongolia were selected as the research objects, and a non-destructive and rapid detection model of alpha(s)1 and kappa-casein in milk was established based on Fourier transform mid infrared spectroscopy. Firstly, the original spectrum of milk was pre-analyzed, and it was found that strongly influenced the spectral absorption of milk. The two main absorption regions of water (1 597 similar to 1 712 and 3 024 similar to 3 680 cm(-1)) were analyzed. It was found that the absorption region of water (1 597 similar to 1 712 cm(-1)) overlapped with that of protein (1 558 similar to 1 705 cm(-1)) (amide I ). By comparing the effect of removing 1 597 similar to 1 712 cm 1, the spectral region of 925. 92 similar to 3 005. 382 cm(-1) was selected as the sensitive band for subsequent analysis. The dimension of the selected full spectrum was reduced manually, and MCCV eliminated the abnormal samples. The support vector machine regression model ( SVR) was established by using eight preprocessing algorithms, such as Savitzky-Golay convolution smoothing (S-G), standard normal variable (SNV). Meanwhile, three feature selection algorithms were combined, such as competitive adaptive reweighting algorithm (CARS) and informationfree variable elimination algorithm (UVE). The results showed that for alpha(s) 1- casein, the SVR model established by the combination of the first derivative and CARS algorithm was the best, the training set correlation coefficient (R-c) and test set correlation coefficient (R-c) were 0. 882 7 and 0. 899 8, respectively, and the training set root mean square error (RMSEC) and test set root mean square error (RMSEP) were 1. 136 3 and 1. 372 6, respectively. For kappa-casein, the SVR model established by the combination of second-order difference and UVE algorithm was the best. The training set correlation coefficient (R-c) and test set correlation coefficient (R-p) were 0. 914 7 and O. 887 7, respectively, and the training set root mean square error (RMSEC) and test set root mean square error (RMSEP) were 0. 473 5 and 0. 558 1, respectively. The results showed that the SVR model based on Fourier transform mid-infrared spectroscopy can be used to detect the content of allergens alpha(s)1 and kappa-casein in milk, and the prediction effect was good. This study can make up for the blank of rapid and non-destructive detection of casein in milk by spectral technology in China.
What problem does this paper attempt to address?