Combination of Cobalt, Chromium and Titanium Nanoparticles Increases Cytotoxicity in Vitro and Soft Tissue Inflammation in Vivo

zhao liu,Hiu Liu,Zhidao Xia,Giorgio Perino,Rachel Vowden,Louise Hughes,Wendy Francis,Ryan Pink,Bin Li,Qi Dahu,Xiao Jun
DOI: https://doi.org/10.2139/ssrn.4053429
2022-01-01
SSRN Electronic Journal
Abstract:Metal nanoparticles released from intended and unintended wear of orthopaedic implants are a leading cause of adverse inflammatory responses and cytotoxicity from the host. Implant wear debris composed of a mixture of metals generated from metal-on-metal bearing surfaces and/or metallic junctions can be more toxic and immunogenic than single metals. This study assessed the effects of three metallic nanoparticles (Co, Cr and Ti) as single metal and in combination on the cytotoxicity of macrophages in vitro and macrophage response in vivo after peri-tibial soft tissue injection in mice. The results demonstrate that Co, Cr, and Ti nanoparticles and their combination were phagocytised by macrophages both in vitro and in vivo. High doses of single metal nanoparticles caused a variable ratio of cell death in vitro; however, the mixture of Co/Cr/Ti nanoparticles was more toxic than Co, Cr and Ti alone at low doses. Intracellular Co, Cr, and Ti distribution in the combined group was heterogeneous and with distinct morphological features. The in vivo experiment showed that there were significant increases in IL1β, IL6, IL-8 and TNFα mRNA expression in peri-tibial soft tissue following administration of Co and combined nanoparticles. In conclusion, this study demonstrates that the combination of Co/Cr/Ti nanoparticles is more cytotoxic than single metals in vitro and generates a higher level of pro-inflammatory cytokines than single metals in vivo.
What problem does this paper attempt to address?