A Study on the Conversion Relationship of Noise Perceived Annoyance and Psychoacoustic Annoyance—a Case of Substation Noise

Di Guoqing,Chen Cong,Yao,Dong Li,Wu Jian
DOI: https://doi.org/10.1177/14613484211068308
2022-01-01
Abstract:The level of annoyance is an important basis to determine the acceptable degree of noise and develop noise standards. Psychoacoustic annoyance ( PA) calculated by Zwicker’s model and perceived annoyance (such as mean annoyance, MA and the percentage of highly annoyed population, % HA) obtained through individual self-reports are widely used. PA and MA (or %HA) cannot be directly compared because the ranges of their values are different. Thus, the conversion relationship of PA and MA (or %HA) needs to be developed. As a case study, the model between PA and MA (or %HA) of substations noise was established and the rationality of model was verified. Results showed that the maximum value of the difference of MA (or % HA) between the calculation result of model and experimental result was less than 0.89 (or 15%). In this way, the perceived annoyance of substation noise samples can be determined by calculation without experiments.