Effect of the Inlet Gas Volume Fraction on the Turbulent Dissipation Characteristics in the Multiphase Pump

Guangtai Shi,Yue Dan,Yexiang Xiao,Zekui Shu,Xiaobing Liu
DOI: https://doi.org/10.1177/09544062211023035
2022-01-01
Abstract:The internal flow of the multiphase pump is complicated owing to its specific structure. To reveal the effect of the inlet gas volume fraction (IGVF) on the turbulent dissipation characteristics, the method of combining numerical simulation based on k-ε turbulence model with experiment was adopted, and the turbulent dissipation of the multiphase pump was quantitatively and qualitatively analyzed in both the pure water and gas-liquid two phases condition. Results showed the vortexes were primarily distributed in the diffusers at different inlet gas volume fractions (IGVFs), near the middle of the first diffuser and the outlet of the next diffuser. At the same time, the larger value of the turbulent dissipation than that in the impellers was concentrated in the inlet and outlet of the impellers and diffusers. In addition, the effect of IGVFs on the turbulent dissipation increased gradually from the hub to the shroud at the inlet section of the first impeller. Moreover, the turbulent dissipation became increasingly unsymmetrical from the hub to the shroud at the outlet section of the first impeller.