Validation of a Spatiotemporal Gait Model Using Inertial Measurement Units for Early-Stage Parkinson’s Disease Detection During Turns

Yifan Yang,Lei Chen,Jun Pang,Xiayu Huang,Lin Meng,Dong Ming
DOI: https://doi.org/10.1109/TBME.2022.3172725
IF: 4.6
2022-01-01
IEEE Transactions on Biomedical Engineering
Abstract:<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Objective:</i> Current inertial-based models were mostly limited to gait assessment of straight walking, which may not be efficient for detecting subtle gait disorders at an early stage of Parkinson’s disease (PD). As PD patients exhibit more severe gait impairments during turns even before the appearance of gait disorders, gait characteristics during turning can provide promise in the identification of early-stage PD. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</i> We proposed a novel spatiotemporal gait model using inertial measurement units that can assess gait performance in both straight walking and turning. Ten healthy young, ten healthy elderly subjects and ten early-stage PD patients were enrolled in the validation experiment. All participants performed a 7-meter walk test consisting of a straight walking path and turns at a self-selected speed. Spatiotemporal gait parameters from the proposed model were compared with the Vicon motion capture system. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Results:</i> A strong correlation of all spatiotemporal parameters (Pearson’s R between 0.82 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\sim$</tex-math></inline-formula> 0.99) between the inertial-based model and the reference was observed. Most measurement differences were within the mean <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 1.96 standard deviation lines. The absolute bias was below 6.21 ms for all temporal gait parameters, 2.19 cm for stride length and 0.02 m/s for walking speed. We show that the proposed model does not only achieve a highly accurate and reliable spatiotemporal gait measurement but also enable the detection of significantly decreased stride length and reduced walking speed in early-stage PD patients at turns compared to the control groups. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Significance:</i> Our model offers a potential approach for early-stage PD detection.
What problem does this paper attempt to address?