Determination of Residual Magnetic Field Based on Optically-Detected Free Spin Precession of Hyperpolarized <SUP>21</SUP>Ne

Sheng Zou,Wei Quan,Xiyuan Chen,Jiancheng Fang,Hong Zhang
DOI: https://doi.org/10.1109/TIM.2022.3150837
IF: 5.6
2022-01-01
IEEE Transactions on Instrumentation and Measurement
Abstract:We report an efficient approach that allows inferring the amplitude and direction of magnetic field, based on optically pumped Ne-21/Cs-Rb magnetometer. The feature that characterizes free spin precession (FSP) of hyperpolarized Ne-21 in external magnetic field provides feasibility for measuring residual field inside magnetic shielding. The measurements are carried out in a Ne-21 cell cohabiting with Cs and Rb vapors, which demonstrate that the hyperpolarized Ne-21 starts freely precessing at Larmor frequency around ambient magnetic field in pump-free state with the advantage of eliminating ac stark shift. Through the Larmor precession and corresponding spectral analysis, we experimentally obtain the weighted average values with related estimated uncertainties: the residual field components in the -axes are (1.41 & x00B1; 0.06), (2.41 & x00B1; 0.06), and (1.86 & x00B1; 0.08) nT, with negative, positive, and negative directions along their corresponding axes, respectively. This research offers foundation for further studying the hyperfine splitting under near-zero field unaffected by Zeeman effect.
What problem does this paper attempt to address?