Frequency Locking System Design and Application to MHz Rate Filtered Rayleigh Scattering Measurements

Frisco R. Koelling,Yue Wu,Christopher Limbach
DOI: https://doi.org/10.2514/6.2022-1166
2022-01-01
Abstract:Ultra-high repetition rate laser diagnostic techniques like Filtered Rayleigh Scattering find a wide variety of applications and implementation for the study of hypersonic and turbulent environments. These techniques make use of vapor cells, which provide strong, narrow, resonant absorption features, to precisely filter selected portions of the scattered spectrum. A system for locking the frequency of an ultra-high repetition rate laser system like a Pulse-Burst Laser, to a resonant absorption feature is therefore useful for lowering measurement uncertainty and improving system reliability. This work presents two methods of laser locking and proposes improvements for each. A laser modulated locking system, wherein laser temperature tuning provides necessary modulation for iodine locking, was able to lock to a Doppler-broadened absorption feature with a deviation of less than 48 MHz over 35 minutes. The second method, which employed an Acousto-Optic Modulator to provide the necessary modulation for locking, was able to lock to a similar iodine feature with less than 12 MHz of deviation over 8 minutes. Future work aims to apply the second implementation to a suitable pulse-burst laser for measurements in a hypersonic ground test facility.
What problem does this paper attempt to address?