Comparison of Neutral-Point Balancing Mechanism in Parallel-Operated T-Type Three-Level PWM AC/DC Interface Converters

Pohan Chen,Kai Sun
DOI: https://doi.org/10.1109/POWERCON53785.2021.9697551
2021-01-01
Abstract:Single-operated T-type three level (T3level) PWM AC/DC interface converters suffer from neutral-point potential (NPP) balancing. Methods, such as modified space vector PWM (SVPWM), zero-sequence injection (ZSI) sinusoidal PWM (SPWM), have been proposed to solve the NPP balancing problem. However, NPP balancing reacts differently when T3level AC/DC interface converters operate parallelly. The mechanism of parallel-operated T3level AC/DC interface converters has been proposed by using modified SVPWM and ZSI SPWM. This paper explains the emergence of NPP unbalancing while paralleling T3level PWM AC/DC interface converters, from the SVPWM and ZSI SPWM point of view, respectively. Also, this paper points out the NPP solution equivalence between the above two methods.
What problem does this paper attempt to address?