Simultaneous Determination of Paracetamol and Amantadine in Human Plasma and Bioequivalence of Its Preparations in Healthy Volunteers by LC-MS
XIAO Xue,ZHANG Dan,ZHAO Ting,YANG Man,QIANG Gui-fen,ZHANG Ya-nan,LIU Hui-chen
DOI: https://doi.org/10.6039/j.issn.1001-0408.2012.18.16
2012-01-01
Abstract:OBJECTIVE: To develop an LC-MS method for the determination of paracetamol and amantadine in human plasma, and to evaluate their bioequivalence in healthy volunteers after given Pediatric paracetamol and amantadine hydrochloride effervescent tables. METHODS: After protein-precipitated with methanol, blood sample was separated on Shim-pack VP-ODS column using the mobile phase consisted of methanol-5 mmol·L-1 ammonium acetate (containing 0.5% formic acid)(45∶55) at a flow rate of 0.3 mL·min-1. Detection was carried out by API 3200 electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. The MRM transitions of m/z 152.2→110.1, m/z 152.3→135.2, m/z 166.1→148.1 were used to quantify paracetamol, amantadine and pseudoephedrine(internal standard), respectively. RESULTS: The linear ranges were 0.080 0~12.0 mg·L-1 for paracetamol (r=0.996 4) and 0.008 0~1.20 mg·L-1 for amantadine (r=0.999 5), respectively. The RSDs ofintra-day and inter-day were both less than 6%, and the average method recoveries were 99.23% and 101.70%. The mean extraction recoveries were (97.0±2.0)% and (92.4±2.7)% for paracetamol and amantadine, respectively. CONCLUSION: The method is effective, sensitive, accurate, specific, rapid, and it is suitable for the determination of paracetamol and amantadine in human plasma. The method can be used for bioequivalence study of Pediatric paracetamol and amantadine hydrochloride effervescent tables.