Research on the Experiment of Oxygen Isotope Fractionation Using Diamond Anvil Cell and Raman Spectra

Shixia Wang,Haifei Zheng
2016-01-01
Abstract:Research studied the oxygen isotope fractionation between quartz and calcite using Hydrogen Diamond Anvil Cell and Raman spectra. The experimental process is as following: put selected phases into sample chamber in DAC and then change temperatures and pressures to reach the isotope fractionation equilibrium in the system. Then phases were scanned by Raman apparatus and fractionation factor was calculated using quantitative analysis of Raman spectra. Heavy oxygen water is considered as third phase to provide 18O. Repeated experiments manifest that quartz and calcite dissolve into heavy oxygen water largely with temperature up to 200℃ or 300℃ and initial pressure of 500MPa, and then quartz and calcite recrystallize during rapid cooling. The whole process makes system of quartz and calcite reach oxygen isotope fractionation equilibrium. There is a linear relationship between ratio of Raman peak intensities and ratio of corresponding amount of substances. So the oxygen isotope fractionation factors between quartz and calcite is calculated as 1.0016 at 300℃. The in-situ experimental study of HDAC is convenient. The ratio of heavy isotope to light isotope in one phase could be measured by Raman spectroscopy accurately. So it is feasible to determine the stable isotope fractionation factor by the technique of Hydrothermal Diamond-Anvil Cell combining with Raman spectroscopy.
What problem does this paper attempt to address?