Analysis of Effect of Grid Harmonics and Unbalance on DAB-Based Three-Phase Single-Stage AC–DC Converter and Solutions

Fengjiang Wu,Xiaoguang Li,Guizhong Wang,Hongchen Liu,Yong Dai
DOI: https://doi.org/10.1109/jestpe.2021.3105674
IF: 5.462
2022-01-01
IEEE Journal of Emerging and Selected Topics in Power Electronics
Abstract:In this article, the actions of the dual active bridge (DAB)-based three-phase single-stage ac–dc converter under the nonideal grid conditions and corresponding solution are researched for the first time. The average state-space model of the converter is built first. Then the effect of grid harmonics and unbalance on the three-phase grid current are analyzed and it reals the grid current harmonics, and unbalance is caused by the distorted grid. In order to solve this problem, a proportional-resonant (PR) + reduced parallel repetitive control closed-loop controller of grid current in the two-phase stationary frame is proposed. The parameter constraint and frequency-domain characteristics of the proposed compound controller are analyzed in detail. The detailed experimental results verify the correctness of the theoretical analysis and the feasibility of the proposed closed-loop controller.