Developing of Polarimetric GPR Calibration Technique
xuan feng,zhengshu zhou,yan zhang,wenjing liang,qiao wang,qi lu,cai liu,lilong zou
DOI: https://doi.org/10.1190/segj102011-001.63
2011-01-01
Abstract:PreviousNext No AccessProceedings of the 10th SEGJ International Symposium, Kyoto, Japan, 20-22 November 2011Developing of Polarimetric GPR Calibration TechniqueAuthors: Lilong ZouXuan FengZhengshu ZhouQi LuCai LiuYan ZhangWenjing LiangQiao WangLilong Zou Jilin University of China ()Search for more papers by this authorEmail the author at [email protected], Xuan Feng Jilin University of China ()Search for more papers by this authorEmail the author at [email protected], Zhengshu Zhou CSIRO Mathematics of AustraliaSearch for more papers by this author, Qi Lu Jilin University of China ()Search for more papers by this authorEmail the author at [email protected], Cai Liu Jilin University of China ()Search for more papers by this authorEmail the author at [email protected], Yan Zhang Jilin University of China ()Search for more papers by this authorEmail the author at [email protected], Wenjing Liang Jilin University of China ()Search for more papers by this authorEmail the author at [email protected], and Qiao Wang Jilin University of China ()Search for more papers by this authorEmail the author at [email protected]https://doi.org/10.1190/segj102011-001.63 SectionsAboutPDF/ePub ToolsAdd to favoritesDownload CitationsTrack CitationsPermissions ShareFacebookTwitterLinked InRedditEmail Abstract Polarimetric GPR is designed to measure the full target scattering matrix for every resolution in the scene. Based on the application of Polarimetric GPR, it is necessary to perform accurate polarimetric measurements to thoroughly investigate signature definition, identification, and classification of substance targets. Accurate data of the scattering matrix is important to extracting biophysical information of the target. In order to identify the characters of substance target, it is necessary to assure that the polarimetric data are not contaminated. Hence, polarimetric calibrate is necessary for the Polarimetric GPR System. Polarimetric GPR requires both the amplitude term and the phase term accurate callbration of channel imbalance and cross-talk to provide meaningful data. Current calibration techniques always ignore high-order teams in order to simplify equations. These techniques are very easy to be performed, but they can't obtain accurate calibration results especially in the phase term. In order to reduce this error, we develop mathematical formulation of calibration to calibrate Polarimetric GPR system's data. In this technique, we use the returns from two simple calibration targets. By measuring several scattering matrices, we can obtain the solutions of all variables as calibration coefficients. Using the calibration coefficients, the calibrated scattering matrix can be calculated. To validate the proposed calibration technique, dihedral corner reflector measurements from 1to 5 GHz with step size of 0.1GHz are performed in the anechoic chamber. The auto-calibrated results show that not only the amplitude term but also the phase term is well calibrated. Permalink: https://doi.org/10.1190/segj102011-001.63FiguresReferencesRelatedDetails Proceedings of the 10th SEGJ International Symposium, Kyoto, Japan, 20-22 November 2011ISBN (print):978-4-938493-07-3ISSN (online):2159-6832Copyright: 2011 Pages: publication data© 2011 Published in electronic format with permission by the Society of Exploration Geophysicists of JapanPublisher:Society of Exploration Geophysicists HistoryPublished Online: 29 Oct 2012 CITATION INFORMATION Lilong Zou, Xuan Feng, Zhengshu Zhou, Qi Lu, Cai Liu, Yan Zhang, Wenjing Liang, and Qiao Wang, (2011), "Developing of Polarimetric GPR Calibration Technique," SEG Global Meeting Abstracts : 1-4. https://doi.org/10.1190/segj102011-001.63 Plain-Language Summary PDF DownloadLoading ...