Open-Path Off-Axis Integrated Cavity-Based Methane Sensing Technique and Experiment
Li Junhao,Zheng Kaiyuan,Xi Zhenhai,Liu Zidi,Zheng Chuantao,Wang Yiding
DOI: https://doi.org/10.3788/CJL202148.1610002
2021-01-01
Abstract:Objective Methane (CH4) is the main component of natural gas; it is a kind of colorless, odorless, flammable, and explosive gas. It has major safety hazards in natural gas transportation and coal mining. The demand for natural gas has gradually increased recently. Generally, natural gas is transported to various areas through pipelines, and the aging of pipelines may cause leakages, which will cause long-term CH4 emissions, resulting in severe environmental problems and huge energy waste. In a closed environment, CH4 leakage is difficult to detect, which leads to potential hazards, such as suffocation and explosion. For example, in factories, coal mines, and other places, when the CH4 concentration in the environment reaches a certain limit (5 6 0-176 0, an explosion will occur, leading to severe safety accidents. Therefore, real-time and accurate CH4 concentration detection in the production environment is paramount to ensure life safety and reduce economic losses. In this study, a near-infrared sensor system based on the open-path off-axis integrated cavity output spectroscopy OA-ICOS) technique was proposed for fast and real-time atmospheric CH4 concentration detection. Further, simulated CH4 leakage detection and the performance of the sensor system were verified through gas sensing experiments. Methos CH4 detection methods include catalyst combustion, electrochemistry, and infrared laser absorption spectroscopy. Infrared laser absorption spectroscopy is widely used because of its in situ quantification. OA-ICOS is a type of laser absorption spectroscopy and has received enormous attention recently due to its long optical path (OP), high robustness, and other advantages. In this experiment, the OA-ICOS technique was used to detect CH4 in real time based on an open OP design. A tunable semiconductor laser with a center wavelength of 1653 nm was used as the light source, and a highly stable optical cavity with a cage structure was fabricated with two high reflectance mirrors of 99.92% apart 35 cm. The optimal position of the off-axis integrated cavity output signal was obtained by adjusting the incident OP. Exploiting the open OP, a CH4 leakage simulation experiment was conducted, which proved that the system had the ability for fast detection of CH4 and natural gas leakage. Through the online real-time Kalman filtering algorithm (KFA), the collected data were dynamically denoised. These experiments laid the basis for further development of the rapid response and on-site use of the CH4 leak detector. Results and Discussions Compared with the effective integral area of atmospheric CH4 in the reference gas cell, the effective mirror reflectivity of the cavity was determined to be 99.93 Yo, which agreed with the reflectivity given by the manufacturer, leading to a 516-m effective OP. The highest signal-to-noise ratio (SNR) of the system, 28, was obtained after Voigt fitting, which indicated that the minimum detection limit of the system was 64 x 10(-9) (Fig. 3). To measure the stability and minimum detection limit of the off-axis integrated cavity sensor system, atmospheric CH4 was measured continuously for 90 min, and related data were analyzed by the Allan variance. When the average time was 4 s, a minimum detection limit of 8 x 10(-9) was achieved (Fig. 4). Using the KFA, the stability of the system was increased 4.3 times compared with the original data (Table 1). Through Allan' s analysis, the detection limit of the system was increased 20.5 times (Fig. 5). Further, a CH4 cylinder with a concentration of 100 x 10(-6) was employed to simulate natural gas leakage (Fig. 6), which verified that the sensor had the ability of short response time and high detection sensitivity for natural gas leakage detection. Conclusions Based on the high-stability cage-based integrated cavity, an off-axis cavity-enhanced CH4 detection system with an open OP was established. With reference to an absorption cell with a known OP, the OP of the cavity was measured to be 516 m. At a concentration of 1.8 x 10(-6), the SNR of the direct absorption signal was 28. Allan variance showed that under 4-s averaging time, the minimum detection limit of the system was 8 x 10(-9). The KFA was used to further depress the absorption signal noise, and concentration fluctuation range was reduced 4.3 times. Through the actual measurement of atmospheric CH4 and simulated CH4 leakage experiment, it was proven that the system had advantages of high sensitivity, high stability, and fast response, which laid the basis for further integration of high-sensitivity sensors used in special fields.