Abstract:Reverse osmosis has been widely utilized in wastewater treatment and been proven to be an effective tool in dealing with radioactive waste as well. However, due to the extremely strict discharge standard of radioactive waste, single-stage RO system can barely achieve the treatment request that multiple-stage RO systems appear to be of the essence. Aimed at boron-containing low-level radioactive wastewater, two different system designs were conducted in this study by using two commercial RO membrane (LE and BW30XFR) in order to achieve different processing goals. Two commercial membranes show completely different rejection properties of nuclides and boron. Both BW30XFR and LE have high nuclides rejection (>96%). However, only BW30XFR has relatively high boron rejection(>78%)compared with LE membrane (58%). In system aimed at decontamination, BW30XFR membrane was used. When system recovery was 75% the decontamination factors (DF) of nuclides were above 103 , meanwhile the DF of boron was larger than 10. In system aimed at separation, LE membrane was used. When the recovery of system was up to 90%, the DF of nuclides were also above 103 but with a lower boron DF below 1.6. The results indicated that more than 55% boron can be recovered from permeate side in separation system. New design schemes show their potential applications for Nuclear Power Plants in the waste liquid treatment.