Fast-Response Oxygen Optical Fiber Sensor Based on PEA2 SnI4 Perovskite with Extremely Low Limit of Detection.

Shunshuo Cai,Yangyang Ju,Yangming Wang,Xiaowei Li,Tuan Guo,Haizheng Zhong,Lingling Huang
DOI: https://doi.org/10.1002/advs.202104708
IF: 15.1
2022-01-01
Advanced Science
Abstract:Oxygen sensor is an important technique in various applications including industrial process control, medical equipment, biological fabrication, etc. The reported optical fiber-based configurations so far, using gas-sensitive coating do not meet the stringent performance targets, such as fast response time and low limit of detection (LOD). Tin-based halide perovskites are sensitive to oxygen with potential use for sensor applications. Here, the halide perovskite-based oxygen optical fiber sensor by combining phenylethylammonium tin iodide (PEA(2)SnI(4)) and tilted fiber Bragg grating (TFBG) is demonstrated. The PEA(2)SnI(4)-based oxygen optical fiber sensor is reversible at room temperature with a response time of about 10 s, and the experimental LOD approaches to an extremely low oxygen concentration of about 50 ppm. The as-fabricated oxygen sensor shows a relative response change of 0.6 dB for an oxygen concentration increase from 50 ppm to 5% with good gas selection against NO2, CO, CO2, H-2. This work extends the sensor applications of halide perovskites, providing a novel technique for rapid and repeatable oxygen gas detection at a low level.
What problem does this paper attempt to address?