The Efficacy of Transepithelial Corneal Cross-Linking in the Treatment of Secondary Keratoconus after Corneal Refractive Surgery
刘彬,林志荣,罗顺荣,方颉,肖显文,谢智文,闫蕾,李学治,董诺,商旭敏,刘昭升,吴护平
DOI: https://doi.org/10.3760/cma.j.cn115909-20230627-00214
2023-01-01
Abstract:Objective::To determine the efficacy and safety of high-fluence accelerated transepithelial corneal cross-linking in the treatment of secondary keratoconus after corneal refractive surgery.Methods::In this prospective clinical study, 36 patients (62 eyes) who were diagnosed with secondary progressive keratoconus after corneal refractive surgery and underwent high-fluence accelerated transepithelial corneal cross-linking (CXL) at the Affiliated Xiamen Eye Center of Xiamen University from December 2019 to April 2021 were recruited. Follow-up was performed at 1 d, 1 week, 2 weeks and 3, 6, 12, 24 months (m) postoperatively. Visual acuity, including uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA), intraocular pressure (IOP), slit lamp examination, corneal topography, in vivo corneal confocal microscopy (IVCM), anterior segment optical coherence tomography (AS-OCT), and corneal endothelial cell (EC) count were performed before surgery and at 3 m, 6 m, 12 m, and 24 m postoperatively. The differences of UCVA, BCVA, spherical diopter, cylindrical diopter, K1, K2, Kmax (front), thickness at the thinnest point of the cornea, corneal endothelial cell density, nerve fiber density and IOP between different time points before and after CXL were analyzed. The overall differences among different time points were analyzed by using one-way ANOVA, and the Bonferroni test was used for pairwise comparison.Results::A total of 31 patients (22 males and 9 females, 54 eyes) with mean age of 28.1±1.2 years were eventually included in this study. There was no statistically significant difference in the UCVA, BCVA, spherical diopter, cylinder diopter, K1, K2, Kmax, and the thickness at the thinnest point of the cornea among all the time points (all P>0.05). Corneal epithelial defect was observed in 11 eyes (11/54, 20%) at day 1 after surgery and recovered within 1 week after the operation. AS-OCT revealed the demarcation line at an average depth of 200 μm in the corneal stroma of 8 eyes (8/54, 15%) at 2 weeks after surgery. One day after surgery, IVCM showed that the nerve fiber density was significantly lower than the preoperative level ( P<0.001), while the superficial stromal cells were swollen and interlaced in a spongy shape. At 3 m postoperatively, the subepithelial nerve fiber density was still lower compared to that before surgery ( P=0.001), and the activated superficial stromal cells still existed with hyper-reflection. At 6 m, 12 m, and 24 m postoperatively, the nerve fiber density was increased and close to the preoperative level ( P>0.05), but the part of the superficial stromal cells lost the enhanced reflection at 12 m and 24 m. No difference of the endothelial cell density was found among different time points ( F=0.39, P=0.642). Conclusions::Refractive status and topographic parameters of patients with secondary keratoconus remained stable without obvious postoperative complications within two years after the high-fluence accelerated transepithelial CXL.