Clinical trial of the domestic multi-channel device of auditory brainstem implant for auditory rehabilitation in patients with neurofibromatosis type 2

王兴朝,赵赋,刘丕楠,王博,杨智君,张晶,李仕维,李朋,王振民
DOI: https://doi.org/10.3760/cma.j.cn112050-20210128-00058
2021-01-01
Abstract:Objective:To evaluate the clinical effect and safety of domestic multi-channel auditory brainstem implant (ABI) device for auditory rehabilitation in Chinese neurofibromatosis type 2 (NF2) patients.Methods:We prospectively enrolled NF2 patients with unilateral or bilateral hearing impairment who needed resection of vestibular schwannoma and were admitted to Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University from December 2015 to February 2016. The surgery was performed via the suboccipital retrosigmoid approach. The ABI electrode was implanted after tumor removal. During the operation, the electrically evoked auditory brainstem response (EABR) was recorded to assist in localizing the cochlear nucleus to ensure that the electrodes were attached to the surface of the cochlear nucleus. The lateral recess was packed with autologous fat to fix the ABI stimulation electrodes. Long-term clinical follow-up was conducted to observe the efficacy and adverse events of the application of ABI.Results:A total of 5 NF2 patients with hearing impairment or loss were included in this study. All the vestibular schwannomas on the surgical side were completely removed. During the operation, all patients were successfully implanted with ABI equipment and EABR waveforms were successfully recorded through electrical stimulation. Device programming and speech training were carried out at 2 to 4 weeks after the operation, and 5 patients could perceive different degrees of environmental sound in a quiet environment. The follow-up time was 57 to 60 months, and all patients had no complications related to craniotomy or device implantation. In 2 patients with bilateral hearing loss before operation, the ABI was used continuously for 54 and 27 months after the device was turned on. The average recognition rates of postoperative environmental sounds were 62.5% and 49.6%, respectively. The average recognition rates of monosyllable and two-syllable words in a closed environment were 42.5% and 33.8% respectively, and the patients had good verbal communication skills with the assistance of lip-reading. Another patient tried device programming and speech training for 2 months due to complete loss of hearing in the contralateral ear, and the device was still not turned on in another 2 patients at the last follow-up because their contralateral hearing remained.Conclusion:Preliminary studies have shown that the application of domestic multi-channel ABI is a safe and effective method of hearing reconstruction, and good intraoperative localizing of the cochlear nucleus and postoperative speech training are the keys to improving the efficacy.
What problem does this paper attempt to address?