Surgical strategy for treatment of type A aortic dissection with small true lumen of the descending aorta

徐志云,唐杨烽,陆杰,薛清,范兴例,张伯尧,张加俊,韩林
DOI: https://doi.org/10.3760/cma.j.cn112434-20200218-00046
2021-01-01
Abstract:Objective:To summarize the results and methods of surgical treatment for type A aortic dissection with small true lumen of the descending aorta.Methods:9 patients underwent surgical treatment for type A aortic dissection with small true lumen of the descending aorta between January 2017 and December 2019 were analyzed retrospectively. There were 7 males and 2 females, mean age of (41.6±9.2) years. Acute dissection were 2 cases, and chronic dissection were 7 cases. Preoerative computed tomography was used to diagnose the dissection and evaluate the true lumen of the descending aorta. This procedure was done in all patients via a median sternotomy under hypothermic CPB with SCP. 4-branched prosthetic graft was used to replace the ascending aorta and aortic arch. The procedures involving the descending aorta: Hybrid surgery using TEVAR. Distal intimal flap fenestration. Implanting the intraoperative stent-graft or prosthetic graft at false lumen for second-step operation.Results:There was no in-hospital mortality. Stroke, Spinal cord, visceral ischemia and lower limbs malfunction were not observed. Reintervention was not found in case with acute dissection during follow-up. One patient who reveived fenestration underwent TEVAR, others with chronic dissection underwent thoracoabdominal aortic replacement 3 months after surgery.Conclusion:Hybrid or staged procedures was a suitable alternative to patients with type A aortic dissection with small true lumen of the descending aorta.
What problem does this paper attempt to address?