Study of the application of healthy orthodontics philosophy in the treatment of skeletal Class Ⅲ malocclusion by force-transmission technique

张凌云,黄文斌,吕汶諠,孙燕楠,张杰妮,张云帆,林久祥,陈斯,韩冰,刘晓默,梁炜
DOI: https://doi.org/10.3760/cma.j.cn115797-20201217-21101
2021-01-01
Abstract:Objective:To investigate the changes of hard and soft tissue as well as the consistency between the long axis of the lower incisors (IA) and the long axis of the mandibular symphysis (MA), ie. the angle between MA and IA, MIA, in cephalometric analysis after successful treatment of skeletal Class Ⅲ malocclusion with Force -transmission appliance and technique.Methods:Pre-and post-treatment cephalograms of 50 skeletal Class Ⅲ patients (male 16, female 34) treated non-surgically with Force -transmission appliance and technique were collected. The average age was (16.5±4.9) years old, ranging from 10 to 29 years old. The average treatment time was (24.6±8.8) months. Cephalometric analysis was performed. Common measurements for both hard and soft tissues as well as the angle between IA and MA (MIA) were included. Mean and standard deviation were calculated for each variable. Paired t-test was performed to evaluate the significant treatment change.Results:Anterior crossbite was successfully corrected. Overjet increased from (-1.47±1.50) mm pre-treatment to (3.77±1.12) mm post-treatment, with (5.24±1.77) mm significant increasement ( P<0.01). Obvious profile improvement was noticed. The distance difference of upper lip and lower lip to Sn-Pg changed from negative value before treatment to positive value after treatment with significant difference ( P<0.01). Inclination of lower incisors decreased -8.54°±5.98° when measured with the angle of lower incisor to mandibular plane, indicating lingual tipping of the lower incisors. However, the post-treatment MIA was 0.31°±5.42°, suggesting the simultaneous occurrence of the alveolar bending and lower incisor retraction. Conclusions:Efficient teeth movement and alveolar bone reformation effect could be realized under the light force delivered by the Force-transmission appliance and technique. Besides the correction of the anterior crossbite and significant profile improvement, the consistency between the long axis of the lower incisors and the long axis of the mandibular symphysis was maintained, which was suitable for the healthy conduction of the occlusal force. Therefore, the Healthy Orthodontics Philosophy could be implemented in the non-surgical orthodontic treatment of skeletal Class Ⅲ malocclusion with the Force-transmission appliance and technique.
What problem does this paper attempt to address?