Research of Droop Control Based on Nonlinear Disturbance Observer for Energy Storage

Wanyu Ji,Jianlong Zou,Linlin Bian
DOI: https://doi.org/10.1049/cp.2019.0656
2019-01-01
Abstract:DC microgrid with energy storage and power electronic transformer (PET) facilitates the integration of large-scale renewable energy resources. In this paper, an improved control method is proposed for energy storage to achieve a switching from PET connected operation to islanding operation with a sudden disconnection of the PET. By introducing the nonlinear disturbance observer (NDO) to droop control for energy storage, no additional current sensors are required to measure the disturbance current when a disturbance occurs in the system. Moreover, a feedforward control is embedded in the droop control for the energy storage unit, which uses the disturbance current estimated by the NDO and enables the energy storage unit to track the disturbance quickly. By using the proposed control method, the transient fluctuations of dc-bus voltage are suppressed and the voltage recovery time is reduced. A DC microgrid model including a PET, a photovoltaic array, an energy storage unit, and DC loads is established. The simulation results have verified the performance of the proposed control method during various operations.
What problem does this paper attempt to address?