RESEARCH AND ANALYSIS OF INTERNAL FLOW PATTERN AND ITS INFLUENCE ON EXTERNAL SPRAY OF A FLOW FOCUSING/BLURRING NOZZLE

Jin Zhao,Zhi Ning,Ming Lv,Chunhua Sun
DOI: https://doi.org/10.1615/atomizspr.2021038872
IF: 1.134
2022-01-01
Atomization and Sprays
Abstract:The experimental observation and research on the internal flow of the flow focusing/blurring nozzle under different flow and structural parameters were carried out. The effects of the tube hole distance, the orifice structure parameters, and the gas or liquid velocity on the flow patterns were investigated. The results show that the flow patterns are significantly affected by tube hole distance, fluid velocity, and orifice diameter, but less affected by orifice length. Larger gas velocity, lower liquid velocity, smaller tube hole distance, and orifice diameter are beneficial to gas-liquid blending inside the nozzle. With the decrease of the liquid velocity, the tube hole distance and the orifice diameter, or the increase of the gas velocity, the liquid cone angle and liquid column diameter in the mixing zone decrease under the stable flow patterns. For unstable flow patterns, the maximum probability gray level of the two-phase flow images inside the nozzle decreases, and the concentration of gray probability distribution curve increases. In addition, the experimental images show that the flow focusing/blurring nozzle has different spray forms, which are closely related to the two-phase flow patterns inside the nozzle. Therefore, internal flow control measures such as controlling two-phase flow rates or tube hole distance are indispensable measures for good atomization quality.
What problem does this paper attempt to address?