Thermal Simulation for a Mechanical Spindle With External Cooler Across Grease Coated Interface

Liang Zhao,Mohan Lei,Hongdi Ren,Jinshi Wang,Shuai Wang,Ben Q Li,Jun Yang,Xuesong Mei
DOI: https://doi.org/10.21203/rs.3.rs-437094/v1
2021-01-01
Abstract:Abstract Spindles in precision boring machine often work in low speed and heavy load without internal cooling, and the thermal error is nonnegligible. So an external cooling system was designed, and the effectiveness of the designed scheme needs to be preliminarily verified by simulation before building the cooling system. Thermal simulations of the spindle with an external cooler require calculating the thermal resistance of the thermal grease-coated interface between the cooler and spindle. Models describing the contact thermal resistance and total thermal resistance for metal contact filled with silicone grease based on solid-liquid interface force equivalence were described in this paper, and experiments were also conducted to verify the accuracy of these models. The contact thermal resistances between the cast iron/copper and silicone grease on flat or arc surfaces were calculated, and the bulk thermal resistance of the silicone grease layer was calculated. The total heat transferred between the cooler and the silicone grease-coated interface of the spindle were calculated. Heat transfer and heat generation in the spindle were calculated, and a finite element model was established to verify the effectiveness of the designed external cooling scheme. Finally, results from experiments for the spindle in different conditions show that the external cooling system decreases the time to reach thermal equilibrium by more than 60%. The RMSE of the simulated thermal elongation is less than 5.7044 μm when the rotating speed of 3000 rpm, and is less than 3.9714 μm when the rotating speed is 1500 rpm.
What problem does this paper attempt to address?