Investigation of Cascade Connection Method to Improve the Insertion Loss of DM Active EMI Filters

Yongxing Zhou,Wenjie Chen,Xu Yang
DOI: https://doi.org/10.1109/jestpe.2021.3112576
IF: 5.462
2021-01-01
IEEE Journal of Emerging and Selected Topics in Power Electronics
Abstract:In this article, a new kind of cascade connection method of differential mode (DM) active EMI filter (AEF) is put forward. Contrary to the conventional idea, it is found different kinds of cascade AEF connections show different insertion loss (IL). Based upon the mathematical analysis, among the eight potential connection methods, two cascade AEF-connection methods are more effective than the other six methods. The IL is much higher than the others. Therefore, the two effective topologies are further analyzed from several perspectives. And the best topology suiting the practical application is found. Several prototypes are fabricated and tested. Experimental results show good agreement with the theoretical calculation.
What problem does this paper attempt to address?