Personalized 3D Printed Tooth-Supported Template as a Novel Strategy for Radiofrequency Thermocoagulation for Trigeminal Neuralgia After the Failure of CT-Guided Puncture
Shaohua You,Xiaoyan Qin,Guoli Zhao,Zeguo Feng
DOI: https://doi.org/10.2147/jpr.s449447
IF: 2.8319
2024-07-06
Journal of Pain Research
Abstract:Shaohua You, 1, &ast Xiaoyan Qin, 2, &ast Guoli Zhao, 1 Zeguo Feng 1 1 Department of Pain Medicine, The First Medical Center of Chinese PLA General Hospital, Beijing, 100853, People's Republic of China; 2 Department of Clinical Laboratory, Shijingshan Teaching Hospital of Capital Medical University, Beijing Shijingshan Hospital, Beijing, 100049, People's Republic of China &astThese authors contributed equally to this work Correspondence: Zeguo Feng; Guoli Zhao, Department of Pain Medicine, The First Medical Center of Chinese PLA General Hospital, Beijing, 100853, People's Republic of China, Email ; Background: Trigeminal neuralgia (TN) is a common form of craniofacial pain, and Radiofrequency thermocoagulation (RFT) has become a commonly utilized treatment modality for TN. However, the complex anatomical configuration of the maxillofacial region and the difficulties inherent in positioning the neck in a hyperextended manner can present challenges for CT-guided punctures. Aim: The objective of this study is to assess the effectiveness and safety of 3D printed tooth-supported template(3D-PTST) guided RFT in patients who have previously undergone unsuccessful CT-guided puncture. Methods: Patients with TN undergoing RFT at the Department of Pain Medicine, PLA General Hospital, from January 2018 to January 2023, were assessed. 3D-PTST guided RFT was employed as an alternative when percutaneous puncture failed. Clinical, demographic, and follow-up data were collected. The duration of the procedure was determined by subtracting the time of anesthesia administration from the time of surgical drape removal. Pain intensity was assessed using the Numerical Rating Scale-11 scale. Treatment effects were evaluated utilizing the Barrow Neurological Institute scale. Incidences of complications related to RFA were documented. Results: Six TN patients underwent 3D-PTST guided RFT. With tooth-supported template guidance, five patients achieved therapeutic target puncture in one attempt with one CT scan. One patient required two attempts with two CT scans. Operation duration ranged from 18 to 46 mins (mean 30 mins). All completed 3D-PTST-guided RFT without difficulty, significantly improving pain symptoms. Four patients had no pain recurrence at 12, 18, 36 and 37 months follow-up, respectively. Recurrence occurred in two patients (at 1 and 13 months). No serious treatment-related complications were observed. Conclusion: 3D-PTST guided RFT is an effective, repeatable, safe, and minimally invasive treatment method for patients with TN who have failed due to difficulty in puncture. Keywords: trigeminal neuralgia, radiofrequency thermocoagulation, tooth-supported template, 3D printing technology Trigeminal neuralgia (TN) is one of the most common forms of craniofacial pain, with an annual incidence of approximately 4.3–27 per 100,000 people. 1 In the face, trigeminal neuralgia appears as sudden, intense, and stabbing pain. This is a chronic, debilitating neuropathy. 2 This pain is often intolerable and hard to be alleviated, greatly undermining the patient's quality of life. 3 Carbamazepine remains the best supported standard medical treatment for TN but may have a 50% failure rate for long-term (5–10 years) pain control. 4 Quintessentially, in cases refractory to treatment using these drugs, invasive treatments including surgery, gamma knife radiosurgery, and interventional therapies treatment is often considered. 4 With the development of minimally invasive treatment technology, radiofrequency thermocoagulation (RFT) has become a popular treatment method for TN. 5,6 This method shows great advantages in precise ablation, but accurate localization of the ablation zone is the first step so the puncture of RFT requires familiarity with the anatomic structure and complete technical support. A conventional CT scan is currently used for CT-guided percutaneous interventions. 7 However, the complex anatomy of the maxillofacial region or the difficulty in adjusting the neck in a hyperextended position may lead to difficulty of CT-guided punctures. The direction and depth of puncture may need to be adjusted, and the puncture target needs repeated explorations, thus leading to more surgical manipulations, larger trauma, and longer exposure to X-ray. And it was a very painful process for the patient and may cause CT-guided punctures to fail. Precise location and puncture, therefore, are of great significance in RFT. In today's world, 3D printing is an emerging technology. 8 With three-dimensional (3D) reconstruction technology, the location, route and dept -Abstract Truncated-
clinical neurology