Critical Temperatures Determination For Monolayer Cable Net Glass Curtain Wall Under Fire Conditions

Yin Bai,Shi-Feng Cheng,Yong-Jiu Shi,Yuan-Qing Wang
2010-01-01
Abstract:Monolayer cable net glass curtain wall becomes the developing trend of large scale curtain wall structure system in China. However, corresponding fire-resisting research work has been lagged. It's important and necessary to give a simple method to get fire-resisting critical temperature of this kind of structure. An FEA software ANSYS was employed to establish Series of numerical calculations models. The principle for determining critical temperature was discussed deeply. The critical temperature table including different spans, grid dimensions and cable diameters is given. It could help designers for getting critical temperature rapidly.
What problem does this paper attempt to address?