Investigation Of The Inside Air Quality For Different Types Of Air Conditioned Vehicles

Yg Wen,Zw Lian,Zh Li,Hm Liu
2004-01-01
Abstract:The inside microenvironment parameters for different types of air conditioned vehicles in Shanghai were measured, which include bus, subway and light railway. These parameters measured are temperature, humidity, CO, CO2, and formaldehyde. The results show that the inside-vehicle temperature and humidity for these vehicles can basically meet the needs of human's thermal comfort. However, the inside-vehicle air qualities are very different. The air qualities for subway and light railway are much better than air quality for bus. CO2 concentration for bus is up to 3223ppm, CO 18ppm, and formaldehyde higher. Therefore, air quality for bus should be improved.