Numerical Study of Bund Overtopping Phenomena after a Catastrophic Tank Failure Using the Axisymmetric Approach

Jiali Huo,Xiaoyang Luan,Yawen Gong,Zhi Wang,Juncheng Jiang,Bin Zhang
DOI: https://doi.org/10.1016/j.psep.2021.07.044
IF: 7.8
2021-01-01
Process Safety and Environmental Protection
Abstract:Hazardous materials are stored in the large tanks in the industry, e.g., a single LNG tank can be as large as 230,000 m3. Therefore, a catastrophic tank failure can cause a disastrous incident. A secondary containment, such as a bund, is required by regulations to control the risk; however, the released liquid may overtop from the bund due to its high kinetic energy converted from potential energy. Computational Fluid Dynamic (CFD) is a proper tool for the bund overtopping study, but there has been significant discrepancy among previous CFD studies. This work developed 2D CFD models of bund overtopping using the axisymmetric approach. A screening study on several turbulence models was performed, and RNG k-s Standard Wall Functions (RNG k-s SWF1) and Large Eddy Simulation WALE (LES WALE) were selected for a detailed comparison in terms of overtopping fraction and flow dynamic behaviour. Both RNG k-s and LES models were systematically validated against experimental data, and the results indicate that LES model is slightly better than RNG k-s model, and both models are acceptable based on the criteria of statistical performance measures. (c) 2021 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?