Comparative Analysis of Gas and Coal-Fired Power Generation in Ultra-Low Emission Condition Using Life Cycle Assessment (LCA)

Libao Yin,Yanfen Liao,Guicai Liu,Zhichao Liu,Zhaosheng Yu,Shaode Guo,Xiaoqian Ma
DOI: https://doi.org/10.1088/1757-899x/199/1/012054
2017-01-01
IOP Conference Series Materials Science and Engineering
Abstract:Energy consumption and pollutant emission of natural gas combined cycle power-generation (NGCC), liquefied natural gas combined cycle power-generation (LNGCC), natural gas combined heat and power generation (CHP) and ultra-supercritical power generation with ultra-low gas emission (USC) were analyzed using life cycle assessment method, pointing out the development opportunity and superiority of gas power generation in the period of coal-fired unit ultra-low emission transformation. The results show that CO2 emission followed the order: USC>LNGCC>NGCC>CHP; the resource depletion coefficient of coal-fired power generation was lower than that of gas power generation, and the coal-fired power generation should be the main part of power generation in China; based on sensitivity analysis, improving the generating efficiency or shortening the transportation distance could effectively improve energy saving and emission reduction, especially for the coal-fired units, and improving the generating efficiency had a great significance for achieving the ultra-low gas emission.
What problem does this paper attempt to address?