Modified Minimally Invasive Percutaneous Bridge Fixation Technique For The Treatment Of Unstable Anterior Pelvic Ring Fractures In Males

Li-Feng Hu,Sheng-Li Dong,Kai Yu,Dian-Ying Zhang
2019-01-01
Abstract:Objective: The objective of this study was to introduce an improved minimally invasive percutaneous bridge fixation technique. After revealing the spermatic cord, the plate was inserted with the spermatic cord placed above the plate to avoid damaging the spermatic cord. Methods: The medical records and follow-up results of 10 male patients with unstable anterior pelvic ring fractures who underwent modified minimally invasive percutaneous bridging fixation technique from January 2015 to January 2018 were retrospectively analyzed. The evaluating indexes including operation time, blood loss, quality of reduction (Matta criteria) and complications were recorded. The evaluation indexes, including the operative time, blood loss, quality of reduction (Matta criteria) and complications, were recorded. Results: The average operative time was 68.5 minutes (range, 50-120), and the average volume of intraoperative blood loss was 78.0 ml (range, 40-200). The quality of reduction was evaluated using the Matta criteria, as follows: excellent in 7 cases, good in 2 cases, fair in 0 cases, and poor in 1 case. The rate of excellent and good reduction was 90%. No instances of iatrogenic spermatic cord injury or inguinal hernia occurred. Conclusion: The modified minimally invasive percutaneous bridge fixation technique avoids iatrogenic spermatic cord injury and offers a safe alternative method for the treatment of anterior pelvic ring fractures in males.