Voltammetric Determination of Hydroxylamine Using A Ferrocene Derivative and Nio/Cnts Nanocomposite Modified Carbon Paste Electrode

Fereshteh Golestanifar,Hassan Karimi-Maleh,Necip Atar,Ercan Aydogdu,Bengu Ertan,Mehdi Taghavi,Mehmet Lutfi Yola,Mousa Ghaemy
DOI: https://doi.org/10.1016/s1452-3981(23)17267-1
IF: 1.541
2015-01-01
International Journal of Electrochemical Science
Abstract:The electrochemical activities of hydroxylamine (HX) as a pollutant compound at a 1,1-bis(phenylacetyl) ferrocenele/NiO/CNTs modified carbon paste electrode (1,1-BPF/NiO/CNTs/CPE) has been studied. 1,1-BPF was used as a suitable mediator for elecrocatalytic interaction with HX. The voltammetric properties of HX at the 1,1-BPF/NiO/CNTs/CPE was investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), chronoamperometry, and square wave voltammetry (SWV) methods. The oxidation peak current increases linearly with HX concentration in the range 0.5-250.0 mu M and the detection limit for HX was 0.2 mu M. The sensor was applied to wastewater samples with excellent performance.
What problem does this paper attempt to address?