Nonlinear Observer Based Fault Diagnosis for an Innovative Intensified Heat-Exchanger/Reactor

Xue Han,Zetao Li,Boutaib Dahhou,Michel Cabassud,Menglin He
DOI: https://doi.org/10.1007/978-981-15-0474-7_40
2020-01-01
Abstract:This paper describes an application of a fault detection and isolation (FDI) scheme for an intensified Heat-exchanger (HEX)/Reactor, where the exothermic chemical reaction of sodium thiosulfate oxidation by hydrogen peroxide is performed. To achieve this, precise estimation of all states of HEX/Reactor, including temperatures and concentrations of different reactants, as well as process fault detection and isolation is completed by a high gain observer. Then, process fault identification is achieved by several banks of interval filters. Finally, an intensified HEX/reactor is used to validate the effectiveness of the proposed strategy. Simulation results are shown to illustrate the performance of the algorithm presented.
What problem does this paper attempt to address?