Ex-Situ Electrochemical Disinfection with the Pbo2 Anode

Wuqi Guo,Hao Xu,Wei Yan
DOI: https://doi.org/10.1016/s1452-3981(23)11204-1
IF: 1.541
2015-01-01
International Journal of Electrochemical Science
Abstract:This research investigated application of tap water prepared by the electrochemical method with the PbO2 electrode in air-conditioner ex-situ disinfection. Influences of different factors on disinfection effects were analyzed. Results show chloride concentration, electro-conductivity, voltage and bacteria species affected disinfection performance conspicuously but pH and the time after electrolysis presented little effects on it. Total bacteria elimination with the method was quick and could be achieved, under specific conditions, in 50 s and 60 s for Escherichia coli (E. coli) and Staphylococcus aureus (SA), respectively. In addition, erosion was not observed on air conditioner surface. This method was found to possess the anti bacteria re-growth ability after disinfection. Overall energy consumption was evaluated as 1.336 kWh.m-(3) and considered economic in application. This method presents a promising approach for air-conditioner disinfection.
What problem does this paper attempt to address?