Experimental Investigation On Condensation Heat Transfer Of R410a On Horizontal Petal-Shaped Finned Tubes

Qianxia Li,Jian Liu,Zhipeng Yan,Gang Zhang,Zhengguo Zhang,Tao Xu,Xuenong Gao
2011-01-01
Abstract:Condensation heat transfer coefficients (HTCs) of zeotropic refrigerant mixture R410a on single horizontal petal shaped finned (PF) tube and three rows of PF tubes with an in-line arrangement were experimentally measured. The objective is to obtain the basic data for film condensation of R410a on the novel enhanced condensation heat transfer tube. Experiments were carried out at saturation temperatures of 39 degrees C and wall subcoolings from o.5 to 6.1 degrees C. The results show that the condensation HTCs on the smooth tube are smaller than those predicted by the Nusselt analysis by 4%. The average enhancement factor provided by the petal shaped finned tube is about 8 and the effect of condensate inundation was significant for the PF tube.
What problem does this paper attempt to address?