Percutaneous kyphoplasty with in vitro digital localization without X-ray contact combined with probe application for the treatment of thoracolumbar vertebral compressed fractures
tang zhanghua,yang huilin,cao xiaojian,yin guoyong,zhang xiaohui,zhou xiaoyu,zhao shu,zhang jie,ji zhaoliang,zhang po,zhu dongcheng
2013-01-01
Abstract:Objective To explore the therapeutic effect of percutaneous kyphoplasty( PKP) with in vitro digital localization without X-ray contact combined with probe application in the treatment of thoracolumbar vertebral compressed fractures. Methods Sixteen cases of T11-L2 thoracolumbar osteoporotic compressed fractures were treated by PKP with no X-ray contact digital localization combined with probe application. According to preoperative DR frontal and posterior iliac crest on the edge of the connection to the external reference from the vertebral pedicle window midpoint distance,the point up the middle to both sides was measured; along the spine pedicle out upper quadrant of distance measurement range,the needle entering point was selected; according to CT and DR side position piece,the needle point of view was chosen; after using C-arm X-ray perspectively 1- 2 times,the vertebral and needle puncture point could be finely tuned and located; through the puncturing,casing implantating,reaming,balloon dilatating,and perspective satisfactory of resetting,the polymethyl methacrylate( PMMA) was implanted. The vertebral Cobb’ s angle,anterior and posterior edge of vertebral body height ratio according to the X-ray films,Visual Analogue Scale( VAS) of the preoperative and postoperative pain score were measured for the evaluation of curative effect before and after surgery. Results The amount of bleeding was 5- 30 ml,averaging 10 ml. Operation time was 30- 60 min, averaging 50 min. No intraoperative spinal cord injury,pneumothorax,PMMA leakage,or pulmonary embolism was reported. Sixteen cases of postoperative X-ray showed accurate vertebral correct positioning. Hospitalization time was 5- 12d,averaging 8d. All patients were followed up for 3- 24 months,averaging 12 months. Pain VAS score decreased from preoperative( 7. 38 ± 1. 09) weeks to( 1. 06 ± 0. 44) 1 week after operation,and maintained stable since. Cobb’s angle from preoperative( 21. 81 ± 2. 56) ° recovered to( 8. 19 ± 3. 41) °1 week after operation,and maintained stable since. Anterior and posterior edge of vertebral body height ratio from preoperative( 51. 10 ± 4. 69) % restored to( 84. 97 ± 7. 44) % 1 week after operation,and maintained stable since. The differences were all statistically significant( P < 0. 01). Conclusion Percutaneous kyphoplasty with in vitro digital localization without X-ray contact combined with probe application for the treatment of thoracolumbar vertebral compressed fractures can obviously reduce the C-arm X-ray irradiation times and the doctor-patient X-ray exposure. It is safe and feasible to osteoporotic compressed fracture operationof T8- L5.