Rapid determination of sulfamethoxazole and trimethoprim illegally added to health products using excitation-emission matrix fluorescence coupled with the second-order calibration method

Lu-Zhu Chen,Hai-Long Wu,Wan-Jun Long,Tong Wang,Gao-Yan Tong,Ru-Qin Yu
DOI: https://doi.org/10.1039/d1ay01391b
IF: 3.1
2021-01-01
Analytical Methods
Abstract:In this work, a simple and fast analytical method based on a self-weighted alternating trilinear decomposition (SWATLD) algorithm coupled with excitation-emission matrix (EEM) fluorescence was developed for the simultaneous determination of sulfamethoxazole (SMZ) and trimethoprim (TMP) illegally added to health products. With the second-order advantage, the proposed method obtained satisfactory results in the presence of peak overlap and unknown interferences. The analysis time for a single sample is only 0.8 minutes. The average spiked recoveries of SMZ and TMP in three health product spiked samples were in the range of 91.0-106.2% and 86.8-107.8%, respectively. The relative standard deviations (RSDs) were lower than 8.6%. In addition, verification parameters including sensitivity (SEN), selectivity (SEL), the limit of detection (LOD), the limit of quantification (LOQ), intra-day precision, and inter-day precision were calculated, and the results show that the proposed method is feasible. The quantitative results of the proposed method were further confirmed by the LC-MS/MS method, which proved that the proposed method was efficient and green for drug-abuse monitoring of SMZ and TMP in health products.
What problem does this paper attempt to address?