Data-driven phase-matched PET/CT: A solution for axial location-dependent respiratory phase in CT

Tao Feng,Gang Yang,Hao Liu,Yu Ding,Yang Lv,Hongdi Li,Yun Dong
2021-01-01
Journal of Nuclear Medicine
Abstract:1420 Introduction: Respiratory motion introduces motion blurring and attenuation and activity mismatch artifacts in PET/CT scans. In a free-breathing PET/CT scan, the data-driven approach allows the acquisition of respiratory information and subsequent motion compensation in the PET images. The 3D CT image is usually scanned prior to the PET scan, and the CT image is also affected by respiratory motion. Different axial positions in the CT image may be in different respiratory phases due to the helical scan approach. For accurate respiratory motion compensation, the phase-information of the CT image is required. The conventional PET-based data-driven approach cannot be used to identify CT’s phase information due to the lack of PET data. In some scans, the patient may also exhibit a slightly larger breathing amplitude during the CT scan that further complicate the attenuation activity mismatch problem. In this study, we propose a data-driven activity/attenuation phase-matching method.\n Methods: Conventional data-driven respiratory gating is first applied to generate gated PET data. Gated PET images were then reconstructed using either a uniform attenuation map or zero attenuation map to avoid activity attenuation mismatch artifacts. Respiratory motion vector fields (MVF) were estimated using the PET data and the deep-inspiration and deep-expiration PET images were generated by extrapolating the MVF. For a fixed axial location, mutual information was calculated between the image patches of the attenuation map and the 4D PET images. The image patch was selected as a 3D volume with reduced axial size centered around the fixed axial location. The respiratory phases of the CT for all different axial locations were calculated using the same approach to generate axial location-dependent phase information. With the generated phase information, the MVF between the CT image and 4D PET images were generated using the original 4D MVF. Patient data acquired using the uMI 780 scanner was collected and tested. Visual comparisons were made to evaluate the performance of the proposed approach.\n Results: Among all the patient data used in this study, the axial-dependent respiratory phase was only observed in a few cases. Among those cases, the proposed method was shown to be able to reduce activity and attenuation mismatch artifacts for different regions (Fig. 1). For patient data with slightly larger respiratory amplitude during the CT scan, a correct respiratory phase was also identified with this approach. However, this method failed for cases with large deep inspiration amplitude.\n Conclusions: In conclusion, we proposed a new method that allows the identification of the respiratory phase in the CT image and can reduce axial location-dependent attenuation and activity mismatch artifacts. The proposed approach does not rely on additional hardware or 4D CT scans.
What problem does this paper attempt to address?