Influence of Partially Failed Actuators of Power Failure on Correction Ability of Deformable Mirrors

Xie Li,Zhong Zheqiang,Zhang Bin
DOI: https://doi.org/10.3788/aos202141.0223001
2021-01-01
Acta Optica Sinica
Abstract:In the long-term operation of a deformable mirror, the piezoelectric actuator is prone to failure due to the cumulative fatigue effect, which leads to the decrease of its correction performance. In this paper, starting from the influence function of a deformable mirror, we set the voltage of the failed actuators to zero and adopt the finite element method to establish the fatigue failure model of the deformable mirror. Furthermore, we mainly analysis the impact of the shape distribution of the distorted wavefront, the type of incident beams, and the arrangement of the actuators. The experimental results show that in the case of partial failure of the actuators, the deformable mirror should perform failure analysis based on the shape distribution of Gaussian random distorted wavefront. From the low-frequency point of view, when the first-circle actuators failed, the deformable mirror has almost the same correction effect on the three incident beams. When the actuator failure is at other circles, the deformable mirror has the worst correction effect on the Gaussian beams. In contrast, from the high-frequency point of view, the deformable mirror has the best correction effect on the flattened Gaussian beam when the actuators failure at different positions.
What problem does this paper attempt to address?