Susceptibility of Individuals with Lung Dysfunction to Systemic Inflammation Associated with Ambient Fine Particle Exposure: A Panel Study in Beijing.

Xi Chen,Chengli Que,Yuan Yao,Yiqun Han,Hanxiyue Zhang,Xiaoying Li,Xinchen Lu,Wu Chen,Xinyan Hu,Yusheng Wu,Teng Wang,Lina Zhang,Mei Zheng,Xinghua Qiu,Tong Zhu
DOI: https://doi.org/10.1016/j.scitotenv.2021.147760
IF: 9.8
2021-01-01
The Science of The Total Environment
Abstract:Background: The underlying mechanism on the susceptibility of chronic obstructive pulmonary disease (COPD) patients to air pollution has yet to be clarified. Objectives: Based on the COPD in Beijing (COPDB) study, we examined whether lung dysfunction contributed to pollutant-associated systemic inflammation in COPD patients. Methods: Proinflammatory biomarkers including interleukin-8 (IL-8) and tumor necrosis factor alpha (TNF alpha) were measured in serum samples collected from 53 COPD and 82 healthy participants. Concentrations of particulate matter with aerodynamic diameter <= 2.5 mu m (PM2.5), carbonaceous components in PM2.5, and PM size distribution were continuously monitored. Linear mixed effects models were used to examine the associations of biomarker differences with particle exposure, between COPD and healthy participants, and across subgroups with different levels of lung dysfunction. Results: COPD patients showed higher differences in IL-8 and TNF alpha levels associated with exposure to measured pollutants, comparing to healthy controls. In advanced analysis, particle-associated differences in IL-8 and TNF alpha levels were higher in participants with poorer lung ventilation and diffusion capacity, and higher ratio of residual volume. For example, an interquartile range increase in average PM2.5 concentration 2 weeks before visits was associated with a 15.7% difference in IL-8 level in participants with the lowest ratio of measured value to predicted value of forced expiratory volume in 1 s (FEV1%pred) (65.2%), and the association decreased monotonically with increasing FEV1%pred. Associations between differences in TNF alpha level and average ultrafine particle concentration 1 week before visits increased gradually with increasing ratio of measured value to predicted value of residual volume/total lung capacity. Conclusions: COPD patients, especially those with poorer lung function, are more susceptible to systemic inflammation associated with fine particle exposure. (C) 2021 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?