Planar Laser-Induced Fluorescence Thermometry in Moderate-Temperature Flow Using OH from Photo-Dissociation of Water Vapor

Multiphase Flow in Power Engineering, Xi’an Jiaotong University,Zhang Zhenrong,Ye Jingfeng,Wang Sheng,Fang Bolang,Hu Zhiyun,Wang Jinhua,Huang Zuohua
DOI: https://doi.org/10.1007/s00348-021-03165-z
IF: 2.797
2021-01-01
Experiments in Fluids
Abstract:Since planar laser-induced fluorescence (PLIF) temperature measurements in a combustion-flow field can only be performed in regions in which OH is abundant (i.e., the reaction and high-temperature burnout zones), this paper investigates the feasibility of using photolysis of dissolved water to generate additional OH in the low-temperature and non-reaction zones of the flow field. Multi-line fluorescence showed that the generated OH had reached thermal equilibrium within 50 ns after dissociation with a fitting temperature of 300 K in room-temperature air. To further verify the technical accuracy, averaged PLIF images from dissociated OH were calibrated and compared with thermocouple measurements in a heated-flow field, and the average deviation in the 423–823 K temperature range was less than 40 K, with a relative system error better than 5%. The results of this paper confirm the feasibility and accuracy of the photo-fragment PLIF (PF-PLIF) temperature measurement in a low-temperature flow field. This makes it an effective complement to traditional PLIF measurements, with great significance for analysis and model validation of combustion processes in low temperature.
What problem does this paper attempt to address?