Preliminary investigation of water distribution at a municipal solid waste landfill

Haijie He,Jiwu Lan,Yunmin Chen,Wei Shi,He Li
DOI: https://doi.org/10.3969/j.issn.1001-0505.2016.S1.008
2016-01-01
Abstract:Due to that water distribution of the landfill which contains multiple daily coverage layers cannot be measured through the water level reconnaissance technologies at present,a new reconnais-sance method is proposed, and experiments are carried out on site to measure the multi-layer water levels. The results show that water level of each waste layer can be measured by implementing drill-ing to a preset depth in combination with effective water sealing of the sleeve, extracting the water in the sleeve and drawing a water level recovery curve; testing results show that four layers of water levels are located at the hole ZK12 , wherein the buried depth of steady water level is 4 . 76 m on the first layer, the value is 10. 35 m for the second layer, the value is 27. 62 m for the third layer, and confined water exists on the fourth layer; different saturation thicknesses of each waste layer are mainly decided by drainage of landfill leachate on each layer.
What problem does this paper attempt to address?