Experimental study on influencing factors of contact resistance on electroosmotic consolidation

XIE Xinyu,LI Zhuoming,ZHENG Lingwei,LI Jinzhu,LIU Yimin
DOI: https://doi.org/10.11817/j.issn.1672-7207.2018.03.019
2018-01-01
Abstract:A series of electroosmosis tests were conducted with aluminum electrodes and beach silt to study the influencing factors for contact resistance during electroosmotic consolidation on the condition of same potential. Anodes with different degree of corrosions and different conductive areas were used in the tests. Rates of drainage, current, potential and water content before and after the tests were measured. The results show that the electrodes corrosion has little effect on contact resistance between electrodes and silt, and there is no obvious difference of drainage for anodes with different degree of corrosions early or during the whole process. Increasing the ratio of the conductive area of anodes and the cross–sectional area of the soil can reduce the contact resistance and improve the conductivity. An optimum ratio of conductive area exists, which is 0.47. It is recommended that the ratio of conductive area should be increased appropriately in engineering applications to improve the efficiency of electroosmosis and its optimum value can be obtained by contact resistance trial tests.
What problem does this paper attempt to address?