Assessment and Early Warning Regarding Hypoxic Injury in a Confined Space Based on the Photoplethysmography

Longzhe Jin,Mengfei Wang,Lu Yu,Mingwei Xu
DOI: https://doi.org/10.11784/tdxbz201811069
2019-01-01
Abstract:The rapid development of industrialization has increased the number of confined space operations. Con-fined space workers are vulnerable to hypoxic injury under an extreme hypoxic environment,where oxygen concen-tration is less than 15%.The traditional monitoring and early warning system of environmental oxygen concentration does not consider the differences among the individual physiological status of the operators.In this study,a new rapid and accurate early warning method for specific hypoxic injury assessment was proposed according to the differ-ent physiological status of the workers.By monitoring the normal oxygen concentration(20%—21%)and the lowest tolerable oxygen concentration(15%—16%)via intelligent wearable equipment,the photoplethysmography signal of the human body was detected,and the differences of the amplitude and fundamental frequency were used for rapid, accurate,and real-time assessment and early warning of hypoxic injury to workers.Herein,we used the wavelet transform and a moving average filter to remove the baseline drift and high-frequency noise in signal processing, obtain a high signal-to-noise ratio(SNR)signal and analyze it in time domain,and then transform the processed high SNR signal into the frequency domain using a fast Fourier transform(FFT).The results of time-domain analysis and frequency-domain analysis show that there are significant differences in the amplitude and fundamental frequency of the human photoelectric volume pulse wave signal in a hypoxic environment compared with that in an environment with normal oxygen concentration(p<0.05).The average decline rate in amplitude and fundamental frequency is 46% and 19%.The critical value of the decline rate is calculated by maximum likelihood estimation method and the principle of 3σ,the critical points of the decline rates of the amplitude and fundamental frequency are determined as 29% and 8.6%,respectively,and the theoretical accuracy of the critical value is 84.1%.A confined space hypoxic injury assessment and early warning table is established based on the calculated critical value.The theoretical accu-racy of the evaluation table is 97.5%.The experimental results show that the accuracy rate of early warning is 91% and that there is no false negative.
What problem does this paper attempt to address?