Gas Holdup and Liquid Circulation in an Internal Airlift Loop Reactor

任源,韦朝海,吴超飞,谢波,肖宏亮
DOI: https://doi.org/10.3321/j.issn:1000-565X.2002.03.019
2002-01-01
Abstract:Gas holdup and liquid circulation in an internal airlift loop reactor were investigated. The reactor consists of one conventional draft tube and three convergence-divergence draft tubes. Experiments were carried out in two-phase systems with air-water and air-CMC (carboxyl methyl cellulose) solutions and in three-phase system with air-water-resin particles, respectively. The two-phase drift-flux model was used to estimate gas holdup for three-phase Newtonian and two-phase non-Newtonian systems. It is shown that gas holdup in convergence-divergence draft tube is higher than that in conventional draft tube and increases with superficial gas velocity. The variation of structural parameters of draft tubes has little effect on gas holdup in the two-phase system and the three-phase system. The mathematical model, which is based on drift-flux model, can describe the liquid circulation in reactor satisfactorily.
What problem does this paper attempt to address?