A Two-Step Iteration Mechanism for Speckle Reduction in Optical Coherence Tomography
Xianghong Wang,Xinyu Liu,Nanshuo Wang,Xiaojun Yu,En Bo,Si Chen,Linbo Liu
DOI: https://doi.org/10.1016/j.bspc.2018.02.011
IF: 5.1
2018-01-01
Biomedical Signal Processing and Control
Abstract:Optical coherence tomography (OCT) provides high resolution and cross-sectional images of biological tissue and is widely used for diagnosis of ocular diseases. However, OCT images suffer from speckle noise, which typically considered as multiplicative noise in nature, reducing the image resolution and contrast. In this study, we propose a two-step iteration (TSI) method to suppress those noises. We first utilize augmented Lagrange method to recover a low-rank OCT image and remove additive Gaussian noise, and then employ the simple and efficient split Bregman method to solve the Total-Variation Denoising model. We validated such proposed method using images of swine, rabbit and human retina. Results demonstrate that our TSI method outperforms the other popular methods in achieving higher peak signal-to-noise ratio (PSNR) and structure similarity (SSIM) while preserving important structural details, such as tiny capillaries and thin layers in retinal OCT images. In addition, the results of our TSI method show clearer boundaries and maintains high image contrast, which facilitates better image interpretations and analyses.