Optimization of a Near‐Concentric Cavity Raman Spectroscopy System for Liquid Sample and Preliminary Results of CO2-3 /HCO-3

Gan‐shang SI,De‐wang YANG,Jin‐jia GUO,Qing‐sheng LIU,Wang‐quan YE,Rong‐er ZHENG
DOI: https://doi.org/10.3964/j.issn.1000‐0593(2019)04‐1086‐06
2019-01-01
Spectroscopy and spectral analysis
Abstract:It is of great significance to study the carbon cycle in the ocean for environmental monitoring and resource detecting . In this field ,one of the most important topics is to study carbonate .There is no direct detection method to monitor carbonate in seawater ,and most traditional detection methods for carbonate are indirect .For example :with seawater sample acidified by phosphoric acid ,the carbonate in the sample can be converted into CO 2 and then be detected .Raman spectroscopy can be used in in‐situ detection and has great potential to detect the carbonate directly .But it’s sensitivity is still a limitation in the practical use of ocean detection .In the hope of developing an approach to directly detect the carbonate in the seawater ,we build a near‐con‐centric cavity Raman spectroscopy system and optimize the main parameters of the cavity (diameter=25.4 mm ,reflectivity =99. 66% @ 532 nm ) including optical window s thickness of the liquid cell ,the optical windows distance at two sides ,and the focal length of the mirrors with simulation software .T he results are listed as follows :(1)T he number of the reflection is at a maximum w hen the focal length is 25 mm for the mirrors with diameter of 25.4 mm ;(2) For the optical window s of the liquid cell ,with smaller thickness ,the light would be denser in the center of the cell ,and the totally luminous intensity in the center plane of the near‐concentric cavity would be larger ;(3) with smaller distance between the optical window s ,the light would be denser in the center of the cell ,and the totally luminous intensity in the center plane of the near‐concentric cavity would be lar‐ger ;After optimization ,the measurement of CO2 -3 and HCO -3 solutions on different concentration levels is carried out using the optimized near‐concentric cavity Raman spectroscopy system .T he spectral signal was pretreated using second order differential and Gaussian filter ,and then calibration curves were established using the peak intensity of the corresponding concentrations . T he results showed good linear relationship between concentration of solution and signal intensity of Raman spectrum ,with R2 of 0.994 and 0.998 for CO2 -3 and HCO -3 ,respectively .We calculated the LODs using the 3 times signal‐to‐noise ratio .T he results showed that the LOD for CO 2 -3 and HCO -3 is about 0.06 and 0.38 mmol·L -1 respectively .T he LODs are lower than the typical concentrations of CO2 -3 and HCO -3 in seawater ,w hich are about 0.2 and 2 mmol·L -1 respectively .Compared to the current re‐ported of the Raman spectroscopy system of in‐suit ocean detection ,the sensitivity of the system has increased by nearly ten times .So it is hoped to apply the system to the in‐situ CO2 -3 and HCO -3 detection inseawater .
What problem does this paper attempt to address?