Experimental Study on the Ash Deposition Characteristics of Heat Exchanger Tubes With Honeycomb Structure

Zhong HUANG,Guan-Jie LIU,Lin CHEN,Lai-Xu DING,Li-Jun YANG,De-Fu CHE
2017-01-01
Journal of Engineering Thermophysics
Abstract:To mitigate the adverse effect of ash deposition on heat exchangers in the boiler outlet duct, a novel kind of heat tube with honeycomb structure on surface (honeycomb tube) was carefully designed and manufactured.Experimental studies on the ash deposition characteristics were carried out on four types of honeycomb tubes and the comparative plain tube by measuring the average weight of ash deposited on the surfaces of each type of tube under two different wind speeds.The results show that the anti-fouling performance of the honeycomb tube with a particular cellular distribution is better than that of plain tube at high wind speed.From the experimental results, it could be deduced that the honeycomb helps to reduce ash deposition via enhancing flow disturbance.
What problem does this paper attempt to address?