Flow Pattern Identification Method for Gas-Liquid Two-Phase Flow in Small Channel Based on Array Sensor

LI Hua-Jun,JI Hai-Feng,HUANG Zhi-Yao,WANG Bao-Liang,LI Hai-Qing
2016-01-01
Abstract:Based on photodiode array sensor and Fisher Discriminate Analysis (FDA),a new flow pattern identification method for gas-liquid two-phase flow in small channel is proposed.In this method,a planar laser sheet is emitted and passes through the transparent small channel,and the exit laser signal is obtained by the photodiode array sensor.The feature vector of the signal is extracted and then the flow pattern is identified by flow pattern classifiers,which are developed by FDA.In this work,four typical flow patterns are investigated and the experiments are carried out in four small channels with different inner diameters.The experimental results show that the proposed method based on photodiode array sensor and FDA is effective,and the identification accuracy is higher than 90%.
What problem does this paper attempt to address?