An Arrangement of Film-Cooling Holes on Endwall to Resist Swirl Effect

Yang ZHOU,Yang ZHANG,Xin-Rong SU,Xin YUAN
2016-01-01
Journal of Engineering Thermophysics
Abstract:Swirl generator is widely used in the lean combustion chamber to reduce NOx emissions and hold the flame stability.Strong swirl at turbine inlet will blow cooling air attachment off the traditional endwall on which the holes are horizontal,reducing cooling efficiency.In order to resist swirl blowing the film away from the endwall,a new holes layout program is with CFD method,according to the design criteria that cooling holes are along the isobars.Experiments show that when the blowing ratio within a certain range,the film cooling effect of optimized endwall is better than the endwall with horizontal holes,and less affected by the swirl disturbance.
What problem does this paper attempt to address?