Ring Coded Imaging for Hard X-ray Focal Spot

ZHANG Mei,HU Hua-si,SHENG Liang,WANG Pei-wei,LI Yang,YUAN Yuan,PENG Bo-dong,ZHOU Hai-sheng,LI Kui-nian
DOI: https://doi.org/10.16568/j.0254-6086.201704006
2017-01-01
Abstract:Ring coded imaging technology with high detection efficiency was put forward to diagnose space distribution for low intensity X-ray spot with several tens to hundred of keV. In this paper, the relations of detection efficiency and signal – noise ratio varied with the ring geometric parameters were researched. The coaxial imaging technology was resolved by employing the design of local micro joins on the ring aperture, and simulating the influence of micro joint area size on imaging quality. The ring aperture imaging system was developed and the Unique-Ⅱ X-ray spot imaging experiment was implemented. The results show that the space distribution of the X-ray spot is approximate a 'saddle' shape, and the intensity in the middle part is lower than both sides along the long axis of the elliptical surface; this conclusion is consistent with pin-hole image; the detection efficiency of ring is evidently more than that of pin. Finally, the effects of and the R-L method and Wiener method used to restore the image are analyzed.
What problem does this paper attempt to address?