Determination of N-Methyl-o-phenylenediamine in Telmisartan by HPLC-QTRAP-MS/MS

Chang-peng ZHOU,Dong-wu WANG,Jie XU,Wen-feng ZHENG,Xiao-yan LIANG
DOI: https://doi.org/10.3969/j.issn.1004-4957.2017.02.019
2017-01-01
Abstract:A high performance liquid chromatography-quadrupole ion mass spectrometric (HPLC-QTRAP-MS/MS) method was developed for the determination of N-Methyl-o-phenylenediamine residues in telmisartan.After extracted with water-acetonitrile (80 ∶ 20,by volume),the telmisartan samples were separated on an Agilent Eclipse XDB-C18 column(3.5 μm,2.1 mm × 100 mm) with a mobile phase of 0.1% formic acid solution-acetonitrile.The electrospray was operated in the positive mode and the samples were monitored under the select reaction monitoring (SRM) mode.As a result,the calibration curves of N-Methyl-o-phenylenediamine showed a good linearity (r > 0.99) in the range of 2.0-50 μg/L.The limits of detection (S/N =3) was 0.5 μg/L,and the limits of quantitation(S/N =10) was 2.0 μg/L.The method has the advantages of simple operation,high sensitivity,good reproducibility,and could be used for the detection of N-Methyl-o-phenylenediamine residues in telmisartan.
What problem does this paper attempt to address?